AI PoE Switch Video Surveillance Solution

- Sep 02, 2020-

Introduction


Whether it is a city or a community, people are paying more and more attention to safety. Monitoring probes cover every corner of life. Escort for the safety of our lives and property.


However, for the construction personnel behind the security monitoring, the hardships and pains they face are unknown to outsiders. As a long-established company in the security industry for many years, the AI PoE switch launched by HRUI,


From the perspective of the construction personnel and users, it has the characteristics of maintenance-free, simple construction, convenient use, and no safety hazards. Solve the pain and difficulty of security monitoring construction personnel.

 

Solution deployment 1: 80-200 point monitoring deployment


Solution Scenario:


200W network high-definition camera, 2 infrared cameras, the number of cameras is 80-200, and the transmission distance does not exceed 100meter.

oF1b68DxRI205Gp5sjI28w

Program Description


Customers use cameras with 200W pixels, and the access layer considers using HR901 series of 8, 16, and 24 Gigabit uplink PoE switches. If the distance to the computer room is greater than 100m, you need to use a PoE switch with an optical port uplink, use a fiber optic transceiver for conversion to calculate at most 200 points, and use a 24-port Gigabit network switch as the core.


Solution value


1: PoE power supply network


2: Multi-port PoE switch networking, less equipment purchase


3: Easy to install, maintain and cost-effective


4: Gigabit fiber access to Gigabit core connection, long-distance transmission network does not freeze


5: 10 Gigabit enterprise-level core switches can be upgraded to three layers, with strong performance, meeting project needs


6: Sufficient port redundancy, easy to expand at any time.


Solution deployment 2: 200-300 point monitoring deployment.


Solution scenario:


200W pixel network HD camera, 2 infrared cameras, the number of cameras is 200-300, the maximum video stream is 4Mbps, and the transmission distance is within 100 meters

2

Program Description


Customers use cameras with 200W pixels, and the access layer considers using HR901 series of classic stable 8, 16, 24 port 100M PoE switches. Connect to the core layer of the computer room with optical fiber


Core layer: Since there are more than 200 points, the network segmentation is involved, and three layers of equipment are needed. Need optical fiber interface to connect with access switch, and enough electrical interface to connect to server and NVR